{"id":7837,"date":"2020-10-22T12:20:50","date_gmt":"2020-10-22T12:20:50","guid":{"rendered":"http:\/\/easyflex.in\/?p=7837"},"modified":"2024-02-06T03:02:26","modified_gmt":"2024-02-06T03:02:26","slug":"earthquake-protection-of-non-structural-elements-in-buildings-5","status":"publish","type":"post","link":"https:\/\/easyflexonline.com\/blog\/earthquake-protection-of-non-structural-elements-in-buildings-5\/","title":{"rendered":"Earthquake Protection of Non-Structural Elements in Buildings"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"7837\" class=\"elementor elementor-7837\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-235f710a e-flex e-con-boxed e-con e-parent\" data-id=\"235f710a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-678900d e-flex e-con-boxed e-con e-child\" data-id=\"678900d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a0e82ac elementor-widget elementor-widget-shortcode\" data-id=\"a0e82ac\" data-element_type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\tBlogs\n<\/span><\/div><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b880b5e elementor-widget elementor-widget-heading\" data-id=\"b880b5e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Earthquake Protection of Non-Structural Elements in Buildings<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-243e87e0 elementor-widget elementor-widget-text-editor\" data-id=\"243e87e0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<p class=\"has-text-align-center has-black-color has-text-color has-normal-font-size\"><em><strong>Technologies for Seismically Bracing MEP Equipment<\/strong><\/em><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center has-black-color has-text-color has-normal-font-size\"><em><strong>Seismic Bracing Assemblies for Conduits including HVAC Ductwork, Piping and Electrical Raceways<\/strong><\/em><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Conduits, including HVAC ductwork, piping, and electrical conduits and raceways, may also require seismic bracing. ASCE 7 says that:<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">HVAC ductwork needs bracing when the duct has a cross-section 6 ft. or larger or when it weighs more than 17 pounds per linear foot, or when it has an Ip=1.5.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Electrical raceways need bracing when they are 5\u201d trade size or bigger. Also, all trapeze-supported raceways weighing 10 pounds per linear foot or more need braces. Electrical components with Ip&gt;1.0 need seismic protection.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Non-sprinkler piping systems may or may not need bracing, depending on whether they are high-pressure systems or convey hazardous materials.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Any system, whether it meets these speci\ufb01c requirements or not, needs seismic bracing in Occupancy Category IV buildings, where the failure of a system renders the building unusable.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">When ductwork, electrical conduits, and piping are hung from the ceiling (whether by rods or trapeze supports), seismic bracing is used to resist horizontal forces. The bracing protects the equipment and its hangers (often threaded rods or trapeze supports) from lateral (perpendicular to the run of the conduit) and longitudinal (parallel to the run of the conduit) shaking.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Seismic bracing in these cases consists of tension-based cable braces or rigid steel braces.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"250\" height=\"188\" src=\"http:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Easy\ufb02ex-Zip-Clip-Cable-Bracing.jpg\" alt=\"\" class=\"wp-image-16518\" style=\"width:500px;height:376px\"\/><figcaption class=\"wp-element-caption\">Seismic Bracing of Pipe using Easy\ufb02ex-Zip Clip Cable Bracing<\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Cable seismic braces link part of the conduit system to a structural member. To resist motion in two directions, opposing cable braces are needed.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"http:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace.jpg\" alt=\"\" class=\"wp-image-16519\" srcset=\"https:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace.jpg 600w, https:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace-300x200.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption class=\"wp-element-caption\">Seismic Bracing of Pipe using Rigid Brace<\/figcaption><\/figure>\n\n\n\n<p class=\"has-text-align-center\" style=\"font-size:12px\">Image source : https:\/\/blog.nvent.com\/caddy\/caddy-bene\ufb01ts-of-rigid-bracing\/<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-black-color has-text-color\">Rigid steel braces perform the same job as cable braces, but only one length of steel is needed. Rigid braces are, however, limited in length, and they won&#8217;t \ufb01t in certain areas and set-ups. Thus, cable braces are a far more \ufb02exible option, as they can be used just about anywhere.<\/p>\n\n\n\n<p style=\"font-size:12px\">Source: https:\/\/www.qrfs.com\/blog\/329-seismic-bracing-for-ductwork-hvac-electrical-systems\/#when<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"739\" height=\"554\" src=\"http:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace-2.jpg\" alt=\"\" class=\"wp-image-16520\" srcset=\"https:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace-2.jpg 739w, https:\/\/easyflexonline.com\/blog\/wp-content\/uploads\/2023\/11\/Seismic-Bracing-of-Pipe-using-Rigid-Brace-2-300x225.jpg 300w\" sizes=\"(max-width: 739px) 100vw, 739px\" \/><\/figure>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Earthquake Protection of Non-Structural Elements in Buildings Technologies for Seismically Bracing MEP Equipment Seismic Bracing Assemblies for Conduits including HVAC Ductwork, Piping and Electrical Raceways Conduits, including HVAC ductwork, piping, and electrical conduits and raceways, may also require seismic bracing. ASCE 7 says that: HVAC ductwork needs bracing when the duct has a cross-section 6 [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":16523,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[1,9],"tags":[],"class_list":["post-7837","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-seismic"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/posts\/7837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/comments?post=7837"}],"version-history":[{"count":11,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/posts\/7837\/revisions"}],"predecessor-version":[{"id":17835,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/posts\/7837\/revisions\/17835"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/media\/16523"}],"wp:attachment":[{"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/media?parent=7837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/categories?post=7837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/easyflexonline.com\/blog\/wp-json\/wp\/v2\/tags?post=7837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}